Product testing laboratory – Capabilities
If we have the belief that we can do it, we shall surely acquire the capacity to do it even if we may not have it at the beginning, Keeping that belief, we have grown and keep growing
| BISS LAB | ||||
|---|---|---|---|---|
| SL | TYPE | MAKE | MODEL | RANGE |
| 1. | Altitude Test Capacity (Temperature, Humidity and Altitude) | Envisys | EA650 | VOLUME: 650L TEMPERATURE RANGE: -73°C to +170°C HUMIDITY RANGE: 10 to 95% RAMP RATE: 5°C/min ALTITUDE RANGE: UP TO 30,000 meters (1Lakh Feet) |
| 2. | Walk-In Type Thermal Test Capacity | Envisys | EWS22K | VOLUME: 22000L TEMPERATURE RANGE: -40°C to +85°C HUMIDITY RANGE: 30 to 95% RAMP RATE: 2°C/min |
| 3. | Temperature/Humidity (Fast Ramp Rate) | Envisys | ET950 | VOLUME: 950L TEMPERATURE RANGE: -73°C to +170°C HUMIDITY RANGE: 10 to 95% RAMP RATE: 20°C/min |
| 4. | Temperature/Humidity Test Capacity | Thermotron | SE3000 | VOLUME: 3000L TEMPERATURE RANGE: -73°C to +170°C HUMIDITY RANGE: 10 to 95% RAMP RATE: 5°C/min |
| 5. | Temperature/Humidity Test Capacity | Thermotron | SE3000 | VOLUME: 3000L TEMPERATURE RANGE: -73°C to +170°C HUMIDITY RANGE: 10 to 95% RAMP RATE: 5°C/min |
| 6. | Temperature/Humidity Test Capacity | Thermotron | SE1400 | VOLUME: 1400L TEMPERATURE RANGE: -73°C to +170°C HUMIDITY RANGE: NA RAMP RATE: 3°C/min |
| 7. | Temperature/Humidity Test Capacity | Thermotron | SM27 | VOLUME: 870L TEMPERATURE RANGE: -73°C to +170°C HUMIDITY RANGE: 10 to 95% RAMP RATE: 3°C/min |
| 8. | Temperature/Humidity Test Capacity | Envisys | ET950 | VOLUME: 950L TEMPERATURE RANGE: -73°C to +170°C HUMIDITY RANGE: 10 to 95% RAMP RATE: 5°C/min |
| 9. | Temperature/Humidity Test Capacity | Design Environmental | Alpha | VOLUME: 900L TEMPERATURE RANGE: -40°C to +170°C HUMIDITY RANGE: 30 to 95% RAMP RATE: 3°C/min |
| 10. | Temperature/Humidity Test Capacity | Design Environmental | Delta | VOLUME: 950L TEMPERATURE RANGE: -40°C to +170°C HUMIDITY RANGE: 30 to 95% RAMP RATE: 3°C/min |
| 11. | Temperature/Humidity Test Capacity | Envisys | ETMG265 | VOLUME: 300L TEMPERATURE RANGE: +10°C to +120°C HUMIDITY RANGE: 40 to 98% RAMP RATE: 1°C/min |
| 12. | Thermal Shock | Envisys | TC100 | VOLUME: 100L TYPE: Basket movement between HOT and COLD Cabinets TEMPERATURE RANGE: -73°C to +180°C RAMP RATE: Less Than 10 Seconds |
| 13. | Hot Air Test Capacity | Terchy | NCK-290 | VOLUME: 350L TEMPERATURE RANGE: Lab Ambient to +200°C |
| 14. | Fluid Contamination Test Capacity | Envisys | EAR160 | VOLUME: 120L TEMPERATURE RANGE: Lab Ambient to +80°C HUMIDITY RANGE: NA RAMP RATE: 1°C/min |
| 15. | Fluid Contamination Test Capacity | Envisys | EAR160 | VOLUME: 120L TEMPERATURE RANGE: Lab Ambient to +80°C HUMIDITY RANGE: NA RAMP RATE: 1°C/min |
| 16. | Fluid Contamination Test Capacity | Envisys | EAR160 | VOLUME: 120L TEMPERATURE RANGE: Lab Ambient to +80°C HUMIDITY RANGE: NA RAMP RATE: 1°C/min |
| 17. | Sealing / Fine Mist | RaaGoma | R129J-13 | VOLUME: 1000L TEMPERATURE RANGE: Ambient |
| 18. | Salt Spray | Envisys | ECS300 | VOLUME: 300L TEMPERATURE RANGE: Lab Ambient to +60°C HUMIDITY RANGE: 40 to 98% |
| 19. | DUST – IP 5X and 6X | Envisys | EDC2700 | VOLUME: 1500L TEMPERATURE RANGE: Lab Ambient to +60°C RANGE: Vacuum Suction up to 5 ports DUST VOLUME Measurement |
| 20. | DUST – JSS | Envisys | EDC1000 | VOLUME: 1000L TEMPERATURE RANGE: Lab Ambient to +60°C HUMIDITY RANGE: 40 to 98% AGITATOR METHOD DUST CIRCULATION |