SLTYPEMAKEMODELRANGE
1.Altitude Test Capacity
(Temperature, Humidity and Altitude)
EnvisysEA650VOLUME: 650L
TEMPERATURE RANGE: -73°C to +170°C                       
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 5°C/min
ALTITUDE RANGE: UP TO 30,000 meters (1Lakh Feet)
2.Walk-In Type
Thermal Test Capacity
EnvisysEWS22KVOLUME: 22000L
TEMPERATURE RANGE: -40°C to +85°C
HUMIDITY RANGE: 30 to 95%
RAMP RATE: 2°C/min
3.Temperature/Humidity
(Fast Ramp Rate)
EnvisysET950VOLUME: 950L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 20°C/min
4.Temperature/Humidity
Test Capacity
ThermotronSE3000VOLUME: 3000L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 5°C/min
5.Temperature/Humidity
Test Capacity
ThermotronSE3000VOLUME: 3000L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 5°C/min
6.Temperature/Humidity
Test Capacity
ThermotronSE1400VOLUME: 1400L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: NA
RAMP RATE: 3°C/min
7.Temperature/Humidity
Test Capacity
ThermotronSM27VOLUME: 870L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 3°C/min
8.Temperature/Humidity
Test Capacity
EnvisysET950VOLUME: 950L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 5°C/min
9.Temperature/Humidity
Test Capacity
Design EnvironmentalAlphaVOLUME: 900L
TEMPERATURE RANGE: -40°C to +170°C
HUMIDITY RANGE: 30 to 95%
RAMP RATE: 3°C/min
10.Temperature/Humidity
Test Capacity
Design EnvironmentalDeltaVOLUME: 950L
TEMPERATURE RANGE: -40°C to +170°C
HUMIDITY RANGE: 30 to 95%
RAMP RATE: 3°C/min
11.Temperature/Humidity
Test Capacity
EnvisysETMG265VOLUME: 300L
TEMPERATURE RANGE: +10°C to +120°C
HUMIDITY RANGE: 40 to 98%
RAMP RATE: 1°C/min
12.Thermal ShockEnvisysTC100VOLUME: 100L
TYPE: Basket movement between HOT and COLD Cabinets
TEMPERATURE RANGE: -73°C to +180°C
RAMP RATE: Less Than 10 Seconds
13.Hot Air Test CapacityTerchyNCK-290VOLUME: 350L
TEMPERATURE RANGE: Lab Ambient to +200°C
14.Fluid Contamination
Test Capacity
EnvisysEAR160VOLUME: 120L
TEMPERATURE RANGE: Lab Ambient to +80°C
HUMIDITY RANGE: NA
RAMP RATE: 1°C/min
15.Fluid Contamination
Test Capacity
EnvisysEAR160VOLUME: 120L
TEMPERATURE RANGE: Lab Ambient to +80°C
HUMIDITY RANGE: NA
RAMP RATE: 1°C/min
16.Fluid Contamination
Test Capacity
EnvisysEAR160VOLUME: 120L
TEMPERATURE RANGE: Lab Ambient to +80°C
HUMIDITY RANGE: NA
RAMP RATE: 1°C/min
17.Sealing / Fine MistRaaGomaR129J-13VOLUME: 1000L
TEMPERATURE RANGE: Ambient
18.Salt SprayEnvisysECS300VOLUME: 300L
TEMPERATURE RANGE: Lab Ambient to +60°C
HUMIDITY RANGE: 40 to 98%
19.DUST – IP 5X and 6XEnvisysEDC2700VOLUME: 1500L
TEMPERATURE RANGE: Lab Ambient to +60°C
RANGE: Vacuum Suction up to 5 ports
DUST VOLUME Measurement
20.DUST – JSSEnvisysEDC1000VOLUME: 1000L
TEMPERATURE RANGE: Lab Ambient to +60°C
HUMIDITY RANGE: 40 to 98%
AGITATOR METHOD DUST CIRCULATION